InstallatIon
Exceeding the recommended pressure and tem-
perature limits from Table 1, or those indicated on the
nameplates of your Jordan Valve Controls valve, can
result in personal injury and property damage. Jordan
Valve recommends the installation of a relief valve to
protect against overpressure situations.
Mark HPX900 and 1500 Series, HPX2D and HPX5T are
designed to meet specific conditions for fluid control,
temperature, pressure and pressure drop. The limiting
factor on these valves can be the body/trim material
combinations. Do not install these valves in any other
applications without first consulting with your Jordan
Valve representative.
1. Inspect the valves for shipping damage and
foreign debris while uncrating.
2. Ensure the pipeline is free of welding slag,
chips and other debris by blowing out the
line before installation.
3. Position the valve on the line so the flow
direction indicator corresponds to the di-
rection of the flow of the pipeline.
4. Jordan Valve recommends the installation
of a standard three-valve maintenance by
pass. This will allow isolation of
the control valve without shutting down
the pipeline system.
5. Install approved gaskets between the
valve body and the pipeline flanges.
6. If the actuator has been shipped sepa-
rately, refer to the mounting procedure in
the applicable instruction manual.
7. If the valve body arrives without packing
installed in the packing box, it will be
necessary to install the packing before
putting the valve into service. To
complete these procedures, follow the
instructions under “packing maintenance”
in this manual.
8. Note: It may be necessary to adjust the
packing to prevent leakage. Prior
to shipping the packing was tightened,
and may require some adjustment
for specific conditions.
IntroductIon
Contained in this manual are installation instructions,
maintenance and parts information for the 2 through
6-inch Mark HPX2D, HPX5T, HPAX2, HPAX5, ASME
Class 900 and 1500 ratings. 2 inch ASME Class 2500
also included. Refer to the appropriate manuals for
instructions for the accompanying actuator, positioner
and additional accessories.
Only trained or experienced personnel should carry
out the operation and installation of all pressure
equipment. If you have any questions regarding the
equipment, contact your Jordan Valve representative.
A serial number identifies each Series H valve and
is stamped on the valve body. Please reference this
number when communicating with your Jordan Valve
representative.
3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com
I & M Mark HPX and HPAX Series
Installation & Maintenance Instructions for the
Mark HPX and Mark HPAX Globe and Angle Style
Control Valves
Warning: Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-
tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or
a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassem-
bling a valve, be sure to release all spring tension.
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - IntroductIon

InstallatIonExceeding the recommended pressure and tem-perature limits from Table 1, or those indicated on the nameplates of your Jordan Valve Control

Page 2 - MaIntenance

-10-Figure 5- 2" Mark HPX2 ValveKey Description Key Description Key Description1 Packing Flange Stud 11 Piston Ring 21 Body2 Packing Flange Nut 1

Page 3 - Packing Leakage

-11-Mark HPX and HPAX Series ValvesParts ListKey Description Stem SizePart Numbers Key Description Stem SizePart Numbers1 Packing Flange Stud1/2"

Page 4 - Replacing Packing

-12-Valve Size Inches QuantityPort Diameter Class 1500Inches mm -425oF to 800oF(253oC to 426oC)801oF to 1000oF(427oC to 537oC)2 2 1-7/8 47.6 1U2216X00

Page 5

-13-Valve Size, NPSYoke Boss InchesValve Stem ConnectionValve Stem TravelDescriptionMaterialin. mm in. mm 316 SSTStandard Bonnet316SSTExtension Bonnet

Page 6 - Trim Removal

-14-Valve Size, NPSYoke Boss InchesValve Stem ConnectionValve Stem TravelDescriptionMaterialin. mm in. mm 316 SSTStandard Bonnet316SSTExtension Bonnet

Page 7 - Trim Replacement

Key 20: Valve Stem for Class 1500 Continued,Valve Size, NPSYoke Boss InchesValve Stem ConnectionValve Stem TravelDescriptionMaterialin. mm in. mm 316

Page 8 - Parts orderIng

-16-Key 20: Valve Stem for Class 1500 Continued,Valve Size, NPSYoke Boss InchesValve Stem ConnectionValve Stem TravelDescriptionMaterialin. mm in. mm

Page 9 - HPX5 Valve Trim

-17-Key 22: Valve Plug for 2 to 6-inch Jordan Valve Class 1500 Globe ValveValve Size InchesValve DesignValve Stem ConnectionPortDiameterMaterialin. mm

Page 10 - Parts Reference

Valve Size, InchesPort Diameter Materialin. mm S31600 (316 SST) S41600 (416 SST)2 1-7/8 47.6 10A4218X012 10A4218X0223 2-7/8 73.0 10A4217X022 10A4217X0

Page 11

Mark HPX and HPaX SerieS Globe and anGle Style Control ValVeS-2-Table 1: Approximate Shipping Weights: Valve and Bonnet AssemblyValve Type Valve Siz

Page 12

-3-Packing LubricationThese instructions are for the lubricator or lubricator isolating valve (Figure 1). If the lubricator or lubrica-tor isolating v

Page 13

-4-Figure 2: Mark HPX and HPAX Series Packing ArrangementsReplacing PackingPrior to beginning any maintenance, it is important to isolate the valve f

Page 14

-5-4. Back off the packing flange nuts (key 2) until the packing is free of constriction against the valve plug stem (key 20). Remove any

Page 15

-6-25. Increase the torque on each nut by an additional 1/4 of the torque value using the standard crisscross pattern. Repeat this pattern

Page 16

-7-Valve Plug Maintenance1. Remove the valve plug and stem assembly (key 20, 22) using the trim removal procedures.2. Follow the instructions for

Page 17

-8-2. For Mark HPX2D and HPAX2: 2.1. New piston rings will be delivered in one piece. The piston ring can be broken in half by scoring a

Page 18 - MKHPXandHPAXIM/0214/2K

-9-Mark HPX Series ValvesFigure 3- 2" Mark HPAX2 ValveFigure 4- Mark HPX5 TrimMark HPX and HPaX SerieS Globe and anGle Style Control ValVeSHPX5 V

Commentaires sur ces manuels